• head_banner
  • head_banner

factory customized Mg Gs Catalog - 750 Thermostat Straight Pipe 1 Pep101970 – Zhuomeng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our merchandise are commonly identified and dependable by end users and will meet continually altering financial and social desires for Mg 550 Accessories, Mg Rx8 Parts Wholesale, Mg 3 Original Parts, Through more than 8 years of business, we have accumulated rich experience and advanced technologies in the production of our products.
factory customized Mg Gs Catalog - 750 Thermostat Straight Pipe 1 Pep101970 – Zhuomeng Detail:

Products information

Products Name PEP101970
Products Application SAIC MG 750
Products Oem No PEP101970
Org Of Place MADE IN CHINA
Brand CSSOT /RMOEM/ORG/COPY
Lead Time Stock, If Less 20 Pcs, Normal One Month
Payment Tt Deposit
Company Brand CSSOT
Application System Chassis System 

Product knowledge

State judgment

When the engine starts cold running, if there is still cooling water flowing out of the water inlet pipe of the water supply chamber of the water tank, it indicates that the main valve of the thermostat cannot be closed; When the engine cooling water temperature exceeds 70 ℃, and there is no cooling water flowing out of the water inlet pipe of the upper water chamber of the water tank, it indicates that the main valve of the thermostat cannot be opened normally, so it needs to be repaired. The thermostat can be checked on the vehicle as follows:

Inspection after engine start: open the radiator water filler cap. If the cooling level in the radiator is static, it indicates that the thermostat works normally. Otherwise, it indicates that the thermostat works abnormally. This is because when the water temperature is lower than 70 ℃, the expansion cylinder of the thermostat is in the contraction state and the main valve is closed; When the water temperature is higher than 80 ℃, the expansion cylinder expands, the main valve gradually opens, and the circulating water in the radiator begins to flow. When the water temperature gauge indicates below 70 ℃, if there is water flowing at the radiator inlet pipe and the water temperature is warm, it indicates that the main valve of the thermostat is not closed tightly, resulting in premature large circulation of cooling water.

Inspection after the water temperature rises: at the initial stage of engine operation, the water temperature rises rapidly; When the water temperature gauge indicates 80 and the heating rate slows down, it indicates that the thermostat works normally. On the contrary, if the water temperature has been rising rapidly, when the internal pressure reaches a certain degree, the boiling water suddenly overflows, indicating that the main valve is stuck and suddenly opened.

When the water temperature gauge indicates 70 ℃ – 80 ℃, open the radiator cover and radiator drain switch, feel the water temperature with your hand. If it is hot, it indicates that the thermostat works normally; If the water temperature at the water inlet of the radiator is low, and there is no water outflow or little water flow at the water inlet pipe of the radiator upper water chamber, it indicates that the main valve of the thermostat cannot be opened.

The thermostat that is stuck or not tightly closed shall be removed for cleaning or repair, and shall not be used.

certificate

certificate
certificate1
certificate2
certificate2

exhibition

certificate4


Product detail pictures:

factory customized Mg Gs Catalog - 750 Thermostat Straight Pipe 1 Pep101970 – Zhuomeng detail pictures

factory customized Mg Gs Catalog - 750 Thermostat Straight Pipe 1 Pep101970 – Zhuomeng detail pictures


Related Product Guide:

It can be a great way to enhance our solutions and service. Our mission would be to build inventive products to consumers with a superior working experience for factory customized Mg Gs Catalog - 750 Thermostat Straight Pipe 1 Pep101970 – Zhuomeng , The product will supply to all over the world, such as: Yemen, India, Slovenia, We have more than 200 staff including experienced managers, creative designers, sophisticated engineers and skilled workers. Through hard work of all employees for the past 20 years own company grew stronger and stronger. We always apply the "client first" principle. We also always fulfill all contracts to the point and therefore enjoy excellent reputation and trust among our customers. You are very welcome to personally visit our company.We hope to start a business partnership on the basis of mutual benefit and successful development . For more information please do no hesitate to contact us..
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Chris from Kazakhstan - 2017.06.19 13:51
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Maria from Croatia - 2017.09.29 11:19
    Write your message here and send it to us

    Related products